Mike Daniels
Technical Specialist
Oreck Manufacturing
Cell 931.287.6252
Eat. Sleep. Fish.
1/25/11
MP-6-7-8 Vacuumed oil pans.
MP-5 The bolt on the “C” axis pivot backed out & it wasn’t making the limit switch every time. Repaired.
MP-6 The robot kept stopping when “Y” axis started in mold. I found that the “Z” axis was loosing position. I tightened the encoder shaft coupler. OK now.
MP-12 Novatec dryer was running hot- not enough air flow on return from hopper. Bill didn’t want to shut it down to check for blockage in hopper. “Run it till
The wheels fall off !! “
1/25/11
MP-10 The wheel press wouldn’t reset without switching the power off. Mark reassigned a reset in the program. Nuts are still oily, & they still want to run
A faster cycle, & wonder why they have trouble pressing parts that are shrinking too much, & then blame us for the press not having enough pressure-
Same old – same old !
MP-9 Vacuumed oil pan.
MP-2 The robot “X” axis position kept changing. The encoder shaft coupler was loose & the plug tie down only had one screw in it & plug was half way out. Repaired.
MP-3 The nozzle heat was unstable. The tip heater didn’t have a clamp & the T.C. was loose. Installed clamp.
MP-6 The gate cutter index cylinder slide broke. Mark made new mounting plates.
up on night shift. Check for set up before it starts.
MP-11 The core pull switch had a loose connection. Repaired. About an hour later, the bottom core pin broke. I pulled the cylinder for tooling. They ended up
having to pull the stationary side so they could burn the pin out.
MP-16 It was giving 2103 alarm code. LS-26 shot size limit alarm.
I emptied the oil vacuum & cleaned out the pan on MP-6. It was full.
MP-19 The core pull switch wires pulled apart when they opened the mold. I butt spliced them back together.
The main thing tonight is to make sure they get MP-22 running. The Star guy will be here first thing in the morning. The label people are coming in later in the morning
to set it up after the programming is done.
Weekend !/14 – 1/16/11
MP-8 Replaced mixer loader hoses with the copper wire lined hoses to cut down on the static that affects the controller.
MP-5 The zone 2 barrel heats dropped out; the mercury contactor went out. Replaced it.
Also the “Y” axis encoder was acting up. It was loose at the shaft coupler.
MP-19 One of the bolts on the rear screw flange broke off, & the other two were loose. Removed the broken one & replaced all three with new bolts & “anti-seize”
MP-16 Large blow back; I cleaned it all off & disassembled the nozzle. I had tooling resurface the end cap & nozzle adapter. Had to do some body work on the covers
& align the sled.
MP-12 The right side palm button on the welder came loose. The mounting nut inside the box was broke, also the guard was missing. Replaced.
MP-7 Blow back- Mark caught it when it happened, but it was still packed & hard. ( Nylon ) Cleaned it out & replaced the nozzle band.
Assembled a work table for Potter.
FYI-
The Password for the new Sonitek Heat Stake is 84.
Thanks
Joshua Ledbetter
Molding Maintenance Manager &
Manufacturing Engineer
Oreck Manufacturing Company
(C) 931-239-3235
(F) 931-646-7615
Mike had to Jerry Rig the Zone 1 Thermocouple on MP26 the other night because of a blow back. I have a new one with the TC Well ordered but there is a two week lead time. Also ordered end caps for 25 and 26- should be here any day.
Joshua Ledbetter
Molding Maintenance Manager &
Manufacturing Engineer
Oreck Manufacturing Company
(C) 931-239-3235
(F) 931-646-7615
Tuesday, January 11, 2011,
Square nuts on MP10 are contaminated again with a sticky goo. Remove track covers and nut from bowl, clean with mold cleaner, scotchbrite and Potter washed and dried nuts.
Current sensor fault on MP14, on nozzle. Tightened screws on nozzle contactor. Contactor could be going bad.
Order more components for new fan housing test station. Sketched up station frame and layout for station.
Getting organized with files for projects, cleaning up some.
Mark McKee
Technical Specialist
Oreck Manufacturing Company
mmckee@oreck.com
PH 931.646.7856
CELL 931.644.5289
FAX 931.646.7615
The Core Problem on MP05 ended up being in the Output Card Plug itself. J1 on the plug is the +24VDC for the first four outputs. If you took the plug off and looked at it, the pins in the socket were broke on one side and bent back on the other.
Thanks
Joshua Ledbetter
Molding Maintenance Manager &
Manufacturing Engineer
Oreck Manufacturing Company
(C) 931-239-3235
(F) 931-646-7615
Thursday, January 06, 2011,
Finished conveyor docking on IML automation cell.
Worked w/ Randy Russell on new Bag Dock Heat Staker station design. Gathered materials for job.
Worked on materials for new Fan Housing Tester.
8 and skate today.
Mark McKee
Technical Specialist
Oreck Manufacturing Company
mmckee@oreck.com
PH 931.646.7856
CELL 931.644.5289
FAX 931.646.7615
Wednesday, Jan 5, 2011
Put MP13 back together, broken butterfly bolts, had to extract one screw. Knockout bars were different lengths. I noticed that the butterfly plate has been welded on and the bolt heads have to be turned down to enter the counterbore, so I think we should order a new one.
Wired the conveyor up for the automation cell for IML, working on the docking locators for it. Received the locate and shuttle tooling from Star.
Made a list of tooling that needs to be made for Josh on the new fan housing tester. Need to order the rest of the purchased item tomorrow.
8 and skate today.
Mark McKee
Technical Specialist
Oreck Manufacturing Company
mmckee@oreck.com
PH 931.646.7856
CELL 931.644.5289
FAX 931.646.7615
12/08/10
Worked on fascia hot stamp.
MP-13 Pulled barrel cover & cleaned off blow back – ¾ down the barrel. I was able to save heater band wiring & the covers , with some minor body work.
MP-19 The DME t.c. was reading low , but the mold heater was running away. I found that the t,c, wire had been pinched behind the mold clamp. Replaced.
12/09/10
MP-13 Pulled the Conair heater to get the part #. There were two possible numbers for that model. I ordered replacements . There are only two heaters
Per zone – 240 v.
MP-10 We cleaned out the nut feeder , Again , & cleaned a box of nuts. Mark adjusted the tracks.
MP-26 The center knock-out mounting stud on the eject. plate fell off. Reinstalled.
I ordered a new adjustment screw & nut for MP-24 spacer adjustment.
I sent the top cover drill out for repair.
I ordered a new replacement motor for the small Solo grinder.
MP05 Robot has been stopping the last week or so randomly with a “Mold is not open- Robot in Unsafe Position error”.
ANYTIME you get this error it means that the mold is not at it’s Open Limit and also the robot is not on either the Y-Up safety switch or Z-Out Safety Switch.
The Power Supply was low and what was happening was the 20 VDC that made it back to the coil on RYS or RZS would allow it to drop out one or both of them every now and again.
Mark adjusted the PS up to around 26VDC and fixed the problem.
Thanks
Joshua Ledbetter
Molding Maintenance Manager &
Manufacturing Engineer
Oreck Manufacturing Company
(C) 931-239-3235
(F) 931-646-7615
12/03/10
MP-25 Replaced a broken air quick connect fitting on robot eoat.
MP-10 Added hydraulic fluid.
I helped Josh & Mark get old press 13 moved out.
I replaced the pneumatic drill on the top cover fixture. I will send the broken one out for repair.
12/04/10
Moved the home sensor block over some for the single cavity connector mold.
Worked on the degate & lable fixture in shop.
MP-5 The tech said that core 2 on the top cover mold wasn’t pulling. I found the bottom core not hooked in to the cylinder.
12/05/10
MP-22 PMed the robot.
I mounted the motor on the polisher test fixture table. It’s the one they test the brush pans on.
Cleaned up some in shop.
MP-5 Replaced the nozzle heater band & fuse. The wire broke off & shorted out.
MP-17 Cleaned up – changed out pads- emptied jug.
Sean fabricated a motor-mount belt tension bracket & a safety switch block. I tapped out the 10 mm holes & mounted the bracket & block. I also installed the blades.
We still need the key for the safety switch & knobs for the block handles. I sent Mark the part numbers.
11/01/10
MP-13 Blow back – tightened down sled & replaced 2 nozz. bands.
MP-15 Solid state relay on nozz. heaters was staying energized – rebooted press & is working fine.
MP-9 Need to look at building new eoat for handle mold. The small cups don’t hold good on textured parts.
Brought grinder in from trailer. The repair parts came in.
11/02/10
MP-14 The timer relay on the thermolator went out. Replaced & Mark ordered more.
MP-11 Mold hanger broke a switch & a fitting on the core cylinder . Mold # 75033. Mark repaired.
MP-3 The Z axis contactor went out. Mark installed a new contactor & overload.
MP-21 A water pipe broke in the stripper plate – fan mold. Tooling removed the broken threads.
MP-5 The wheel press staying down after pressing the wheels in. Someone had turned the pressure up too high & the over stroke switch was making.
Readjusted to 100 psi.
10/27/10
MP-12 Blow back - the mold wasn’t centered in the check ring. I replaced one nozz. adapter heater band.
MP-17 Cleaned up oil.
10/28/10
MP-10 Cleaned oil from nut feeder. I gave them some alcohol & a bucket to clean nuts. Mark emailed engineering so they can contact vender.
D-32 Alarm 11 - The turntable switch was out of adjustment.
MP-6 They changed to polycarb on the base plate. Mark turned the pressure up on the wheel press.
MP- 25 Set up chute for hokey handle water cooling tank.
10/22/10
MP-16 Installed a flow control valve on the eject. retract line.
MP-21 They changed the nozzle tip from a button tip to a 2”. I installed a tip heater band and replaced the adapter band that was burned out.
MP-17 Cleaned up oil, emptied jug, & replaced pads…………………………..
MP-4 At 5pm the tech told me the robot crashed. I checked & the “Y” axis had extended to the mold & hit the stationary side. It broke the “C” air
cylinder, two vacuum fittings, & bent two suction cup brackets. I removed the eoat & cylinder & turned it over to Sean Man.
10/23/10
MP-9 The “Z” axis set point was drifting. I checked the encoder – everything was tight. I tightened the “Z” axis belt & rebooted the robot. It looks
consistent now.
MP-22 The hotstamp heats kept going off. I checked all the heater connections. I reseated the T.C. plug on the board. It’s running & hasn’t cut off
in four hours.
MP-11 The PS-2 pressure switch on the injection unit quit working. I replaced it.
Made program changes to the PLC and Quickpanel on MP5 Robot for an I/O Monitoring Screen. The new screen can be accessed from the main menu. Please try to check it out and use it as much as possible, we need to see if everything works correctly and if we want any more changes. If you have any questions or suggestions please let me know.
Picked up an inline, directional control valve for the eject retract on MP16 to slow down breakage of butterfly bolts. Ronnie installed and set it to smooth out the banging on the retract.
We received the replacement seals for the Novatec Proportional Valves. They are in MRO.
Small ice cube relays were ordered for the AEC Robot control cabinets, RB, RYS, and RZS.
The new butterfly plate, guide rod, and knockout rods for MP20 were finished and
Helped Mitch set the welder outputs in MP12.
Tightened and realigned clamp cylinder on MP10 connector welder.
Ordered the steel for Robot Riser spacers. Josh got the prints for the machine mounts. The steel should be here this Saturday. We can start making them next week.
Started working on In Mold Labeling Project
Changed out more of the 3 pin color pumps connectors to 2 pin.
Technical Specialist
Oreck Manufacturing Company
mmckee@oreck.com
PH 931.646.7856
CELL 931.644.5289
FAX 931.646.7615
Good Morning Gents,
Lots of little stuff last night like plug it up turn it on.
Had issue with mp5 the cores not always working reseat I/O boards and they seemed to work for a sort while. Finally found a very loose wire on board in #6 slot in control rack.
Hasn’t missed a lick since.
Not really anything else major to speak of.
Have Great Day
Mike
I emptied all the overflow jugs on the presses, cleaned up the oil on MP-17, & vacuumed the pan on MP-6.
MP-4 I made an eoat for the rear steemer handle mold & installed it.
Somebody left the air poppet fittings out of the mold. We found them in tooling & installed them.
D-6 ran in the maint. shop for nearly 24 hrs. & the beds never did dry. I started pulling the desiccant cans to change them out.
10/8/10
MP-16 The touch pad on the Milacron dryer wasn’t working. I called & requested a quote from Uni-Dyn.
MP-11 The core pull hydraulic hose came loose at the threads behind the quick-connect. It was never tightened. I cleaned up an oil pond around the press.It ran all night
& nobody saw it leaking.
Dryer- D-7 on the mezzanine had a bad regin. contactor. Replaced
10/9/10
Mezzanine - I played musical dryers all day to get one that worked. I pulled D-6 off station 2 & took it to the shop. I replaced it with D-32 from floor. I looped out
D-7 on station 4, to try & dry the beds. I also loop out D-6 in the shop to see if it would dry out. After several hours, D-7 came down to – 40, so I put it on station 2.
D-32 wasn’t drying, so I looped it out. D-32 & D-6 , after 6 to 8 hours, the dewpoint is finally starting to drop somewhat.
MP-3 Installed core plug on the steemer handle mold.
MP-1 Die height alarm- The position had to be moved manually before the auto die height function would work.It was too close to the end of the threads to lock in.
After that, it was getting an eject alarm----- I found the knock-outs weren’t tied in. OK now.
MP-3 Robot was alarming out – not seeing eject. forward. Found the multi-eject. on the special option page was not turned on. OK now.
MP-23 I worked with Mark M. setting up the new eoat for the 2 cav. fan mold 74022.
MP- 6 The mold wouldn’t close. I checked all the limit switches & found the operator side gate switch wasn’t making. I adjusted the jam-
bar flag.
MP- 1 It was getting a lube alarm. Josh reset the manual lube count to the maximum setting.
Two molds fell off the pallet while being transported. We got them stood up & checked them out for damage. Mold 76003 cav.1 had a broke strap bolt.
76003 cav. 2 had a pinched wire & cracked mounting brackets on the heater junction box. All is repaired except the box. We can fix it when they
Finish the run on MP-6.
MP-17 Cleaned up oil .
MP- 6 Vacuumed out oil pan. Oil vac. is still behind the press.
MP-15 Oil leak. I am ordering a new pump seal for this one.
We were having problems with thermolators cutting off on MP-2 & 3. ( chiller supply ) The flow & temp looked OK. In tooling the EDM was over heating.
they bled the line & got quite a bit of air & rusty water out. After that, the thermolators straightened out. There must have been an air lock.
Ronnie Coleson was notified.
I installed the new overload on MP-5. They will hang the base plate back in.
If the hydraulic oil doesn’t come in today, I’ll call them in the morning.
Good morning Gents,
Typical night in molding no major problems. Mp2 has a issue with the core switches, the i/o page shows they are set when they are and pulled when they are but when put in cycle clamp moves about 6in. then stops and reads core 1 not pulled when it is. We ran it on timers with no problems.
Repaired 3 more trollies
Replaced prox switch on fixture on mp10
Replaced blown nozzle heat fuse on mp2
Have a great day
Gone Fishin
Mike
MP5 keeps tripping overload on pump. A complete contactor and overload should be here Wed. UPS Red.
They moved the baseplate mold to #1.
Lexan sheets came in today. Been trying to replace broken panels in trolleys as I can, if you pick up where I left off, measure each one individually as there are slight differences between them.
Mark McKee
Technical Specialist
Oreck Manufacturing Company
mmckee@oreck.com
PH 931.646.7856
CELL 931.644.5289
FAX 931.646.7615
One of the bucket tumblers quit working. I just had to tighten the belt. I asked Elaine to order two more motors for the two spare tumblers. I put them
in the trailer for now.
MP-7 The bolts vibrated loose & the deflector fell in the grinder. I cleaned it out & restarted it. It still needs a new deflector.
MP-2 I hooked up the cores to the eject circuit for them. Also replaced a broken core switch on the stationary side. One of the mold heater plug pins was pushed in
& not making contact; repaired.
MP-6 The clamp wouldn’t close. I tried probing the valve, no luck. When I opened the cabinet to check the input & restarted the pump, it started working.
I worked on stripping & scrapping equipment in shop. I cleaned out the cabinet in the bone yard.
I finished up on the grinder that Sean put back together. We put it back in service Sunday.
Cleaned up oil on 17 & 21.
I put the gaylord of spare parts in the trailer.