Good morning all,
Quiet night no major problems on molding floor. I put the new control in matsui drier, its still in shop I let it run for around an hr or so with no problems so I green tagged it.
Have a great day
Mike
Good morning all,
Quiet night no major problems on molding floor. I put the new control in matsui drier, its still in shop I let it run for around an hr or so with no problems so I green tagged it.
Have a great day
Mike
MP-16 Dryer D-9 Temp. probe alarm. They were running it at 250 & the High limit was at 200. Reset- OK.
Loader #6 on mezzanine not loading. The loader flap was stuck & not making the switch.
MP- Lube cycle alarm. Reset the counter & installed a new tube of grease.
MP-The boss fitting on the top inj. pump line was leaking. I took the line & fitting off ; the o-ring was cut. Mark had to go to IR-G to get
the right o-ring. He reinstalled it – looks good.
MP-9 The C- axis on the robot wasn’t working. I found a cracked air fitting at the solenoid. Also the coil piston was gummed up.Cleaned &
reinstalled – Working good.
Good morning,
Fairly peaceful night, minor adjustment on nippers on the fixture on press 3.
Tried to calibrate gravity loader on the dryer that is behind press 8 it still not acting right
Removed another small nozzle leak from press 15 no damage only down couple minutes.
Have good day
Mike
Hello All,
They finally released some funds to order parts to repair one of the two grinders we still have tore down. I chose the bigger one and ordered the parts for it today. I’ll order the parts to repair the little Solo grinder next month.
Also, I’m got approval to do a CER tomorrow for two New Grinders specified for Pelethane (Santoprene). I chose to go with AEC because they have recently purchased
Attached are the specs and quote so that everyone can check it out.
Thanks
Joshua Ledbetter
Molding Maintenance Manager
Manufacturing Engineer
Oreck Manufacturing Company
931-239-3235
Good morning,
I helped
Have a great day.
MP-20 Nozzle adapter heater band was bad---- replaced.
MP-25 The cores were backwards. Normally the core cylinder is fixed & the shaft moves ; on the hokey handle mold the cylinder moves , so the
set & pull lines hook up backwards.
MP-25 Replaced the motor overload on the grinder.
MP-2 The rear zone heater - mercury contactor blew up. Mark & I contacted Walter Marcum. We cleaned out the cabinet & disposed of the mercury
In the drum in the recycle room. Installed a new contactor.
Upgraded robot displays with speed control adjust on MP3, 8, 9, 10, and 11 today.
Ran chiller water to the dryer behind MP8 off the machine manifold and hung a sign on the ball valves, not to shut off unless machine pump and dryer are shutdown first.
Mark McKee
Technical Specialist
Oreck Manufacturing Company
mmckee@oreck.com
PH 931.646.7856
CELL 931.644.5289
FAX 931.646.7615
MP-20 The cycle start timer wasn’t working. We saw input 14 on the plc flickering. Mark traced the wire & found a loose connection in the robot wiring.
MP-5 Added hydraulic fluid.
MP-2 & 6 PMed.
MP-20 Mold # 77015 – The DME heater plug on the mold had a broke pin – zone 6. I replaced the plug. The wires were short in the box so I had to add another splice in the wiring. I’ll have tooling let me
know when the mold comes back & I’ll fix it right.
MP-5 Pump motor overload tripped. Injection valve – off fault. Mark said the pack time was set too high. He lowered the time & it hasn’t stopped again.
MP-3 Zone 3 barrel temp was running away. The mercury contact was stuck- replaced it.
I worked on the bag clip hot stamp. The heat kept dropping out. I found a loose solder connection on the board. I re- soldered it & I have been trying it out
In the shop. So far I hasn’t cut off.
R. Upchurch
I vacuumed out the rest of the oil pans & emptied the waste oil drum.
I installed the QVC fascia pad & set up the hot stamp. The pad isn’t contoured to the part, so it took a lot of shim tape. They changed the location of the artwork
AGAIN !!!!! I located the new pad so they can change back to the old one without moving the mounting plate.
R. Upchurch
MP-23 & 25 Replaced broken lube fittings – ( tie bar & skate )
MP-14 Replaced broken ¾” water supply line on thermolater.
MP-8 Blender regrind valve not opening; may be static causing the controller to lose set points. Will try a ground wire on it.
Cleaned out oil pans on MP-6 & 7.
MP-25 Lost ejector back position; Mark & Jason adjusted the encoder.
R. Upchurch