MP25 adjusted the part verify switch
Worked on PMs
Overall good night
MP20 Replaced the ejector cylinder, end cap, piston rings, and seals.
MP-25 Installed a relay on the robot up stroke; to prevent the cycle from stopping when the grippers drop the sprue.
MP-5 Core 2 not reading pull. The switch on the bottom cylinder wasn’t making.
MP-19 Ordered a seal kit for the sled cylinder.
1/29/2011
MP-11 Replaced missing switch levers on control panel.
MP-10 Added two more quick connects on air manifold. One 3/8” & one ½”.
D-32 on mezzanine wouldn’t restart—Bad process blower contactor—out of stock. I was going to swap with D26, but the process blower motor was locked up
& had two blown fuses. I put a 100# per hour dryer in to get by---- no spare 200# .Had to wait till Sunday to pull the two dryers down & take to the shop
to repair – “ No Overtime”
1/30/2011
D-32 Need to order a contactor for this one. Old one is on desk.
D-26 I replaced the process blower unit.
MP-13 The ejector lost it position. I found the collar that the transducer read position from had fallen off. Re installed.
I am leaving early today, because I stayed over an hour last night.
MP-26 Installed new front zone T.C. probe.
MP-5 Top & bottom cores leaking. I tightened a fitting on the top core. The bottom core is leaking from the set switch seal. I tightened it; they were in a hurry to run samples, so I let them have it. I’ll check it out when it’s down again.
MP-2 The rear zone heats dropped out again so I replaced the contactor.
MP-22 I re soldered the plug back on for the static charger. Josh & Jason had taken it loose to rig up a foot control switch to run some parts in manual.
1/25/11
MP-6-7-8 Vacuumed oil pans.
MP-5 The bolt on the “C” axis pivot backed out & it wasn’t making the limit switch every time. Repaired.
MP-6 The robot kept stopping when “Y” axis started in mold. I found that the “Z” axis was loosing position. I tightened the encoder shaft coupler. OK now.
MP-12 Novatec dryer was running hot- not enough air flow on return from hopper. Bill didn’t want to shut it down to check for blockage in hopper. “Run it till
The wheels fall off !! “
1/25/11
MP-10 The wheel press wouldn’t reset without switching the power off. Mark reassigned a reset in the program. Nuts are still oily, & they still want to run
A faster cycle, & wonder why they have trouble pressing parts that are shrinking too much, & then blame us for the press not having enough pressure-
Same old – same old !
MP-9 Vacuumed oil pan.
MP-2 The robot “X” axis position kept changing. The encoder shaft coupler was loose & the plug tie down only had one screw in it & plug was half way out. Repaired.
MP-3 The nozzle heat was unstable. The tip heater didn’t have a clamp & the T.C. was loose. Installed clamp.
MP-6 The gate cutter index cylinder slide broke. Mark made new mounting plates.
up on night shift. Check for set up before it starts.
MP-11 The core pull switch had a loose connection. Repaired. About an hour later, the bottom core pin broke. I pulled the cylinder for tooling. They ended up
having to pull the stationary side so they could burn the pin out.
MP-16 It was giving 2103 alarm code. LS-26 shot size limit alarm.
I emptied the oil vacuum & cleaned out the pan on MP-6. It was full.
MP-19 The core pull switch wires pulled apart when they opened the mold. I butt spliced them back together.
The main thing tonight is to make sure they get MP-22 running. The Star guy will be here first thing in the morning. The label people are coming in later in the morning
to set it up after the programming is done.
Weekend !/14 – 1/16/11
MP-8 Replaced mixer loader hoses with the copper wire lined hoses to cut down on the static that affects the controller.
MP-5 The zone 2 barrel heats dropped out; the mercury contactor went out. Replaced it.
Also the “Y” axis encoder was acting up. It was loose at the shaft coupler.
MP-19 One of the bolts on the rear screw flange broke off, & the other two were loose. Removed the broken one & replaced all three with new bolts & “anti-seize”
MP-16 Large blow back; I cleaned it all off & disassembled the nozzle. I had tooling resurface the end cap & nozzle adapter. Had to do some body work on the covers
& align the sled.
MP-12 The right side palm button on the welder came loose. The mounting nut inside the box was broke, also the guard was missing. Replaced.
MP-7 Blow back- Mark caught it when it happened, but it was still packed & hard. ( Nylon ) Cleaned it out & replaced the nozzle band.
Assembled a work table for Potter.
FYI-
The Password for the new Sonitek Heat Stake is 84.
Thanks
Joshua Ledbetter
Molding Maintenance Manager &
Manufacturing Engineer
Oreck Manufacturing Company
(C) 931-239-3235
(F) 931-646-7615
Mike had to Jerry Rig the Zone 1 Thermocouple on MP26 the other night because of a blow back. I have a new one with the TC Well ordered but there is a two week lead time. Also ordered end caps for 25 and 26- should be here any day.
Joshua Ledbetter
Molding Maintenance Manager &
Manufacturing Engineer
Oreck Manufacturing Company
(C) 931-239-3235
(F) 931-646-7615
Tuesday, January 11, 2011,
Square nuts on MP10 are contaminated again with a sticky goo. Remove track covers and nut from bowl, clean with mold cleaner, scotchbrite and Potter washed and dried nuts.
Current sensor fault on MP14, on nozzle. Tightened screws on nozzle contactor. Contactor could be going bad.
Order more components for new fan housing test station. Sketched up station frame and layout for station.
Getting organized with files for projects, cleaning up some.
Mark McKee
Technical Specialist
Oreck Manufacturing Company
mmckee@oreck.com
PH 931.646.7856
CELL 931.644.5289
FAX 931.646.7615
The Core Problem on MP05 ended up being in the Output Card Plug itself. J1 on the plug is the +24VDC for the first four outputs. If you took the plug off and looked at it, the pins in the socket were broke on one side and bent back on the other.
Thanks
Joshua Ledbetter
Molding Maintenance Manager &
Manufacturing Engineer
Oreck Manufacturing Company
(C) 931-239-3235
(F) 931-646-7615