Mp#4-conveyor quit. Reinstalled chain and readjusted belt tracking.
Working fine now.
Mp#5-overtravelled once and had to be rehomed, problem was a loose cable connection in panel where someone had moved the cabinet.
Mp#6- techs couldn't get the conveyor to work, jumper was not connected.
Mp#19- Nozzle was not working, found loose wiring connection, no further problems.
SB#2- Ran out of material, cap was off of header on catwalk.
Hot stamp press on #21- showing "eater control error". Found bad connection on thermocouple. Replaced the thermocouple (Type J) no further problems.
Call if there are any questions. I did check out the manual on the new star and on behalf of this shift, thanks for the new robot!~
Sean
Friday, May 14, 2010
Sunday, May 9, 2010
" C " Shift
Built & installed three more conveyor trays; only need one more to complete all.
MP-22 Checked & set torque on screw gun.
MP-1 thru MP-12 Checked & lubed tie bars—blew out cabinet filters. ( MP-6 & 8 need new cabinet fans )
MP-11 Cleaned up oil under clamp unit – Clamp seal needs to be replaced.
MP-17 Discharge line came off of our recirculating pump—blew oil on floor-- cleaned up & replaced hose.
R.Upchurch
Molding Maint.