Saturday, February 12, 2011
2.11.11 Sean Kearns
There were problems getting the shaft yoke off because it was made with a set screw which had mashed the threads and caused them to gall coming out and going in. There was no help for it and it may have already been that way.
If it comes out next time I will turn it down and drill through it and put a bolt in it.
Mp#14- Need to order a sled seal kit for it also.
Restocked the hydraulic oil spill kit with everything I could find to put in it. They need to post a list inside the lid of what it needs to contain.
Because of the recent safety alert, and the fact that I have seen so many people unsticking grinders with them still plugged up, I posted a copy of the alert on every grinder in molding. This way no one can say they did not know about it.
Call if there are any questions.
Sean
Ronnie Upchurch
MP-8 No screw function. The screw cold start prevent wasn’t working on the front zone controller. We replaced the controller & it’s working fine.
I’ll take the old one to Craig & see if he can fix it.
New Novatec dryer – I installed the new motor & speed controller & set the speed at about 8 rph. I dry cycled it for 5 hours & gave it back to them.
MP-16 No nozzle heat. I checked the heater bands & power from the contactor. The only thing I saw was one heater wire that may not have had a good connection
at the wire nut. OK now.
Matsui dryer on MP-14 was in high heat alarm. It wouldn’t clear so I powered it down. When it came back on I let the regen. heat come up before I hit the
Dry button; the process heat came up & it’s running fine. I think they had just moved this dryer & didn’t let it cool down.
MP-15 The nozzle was freezing off & it blew out one time. “ Delrin” They had a 1” band on a 2” nozzle tip & it was slid all the way back. I put a 2” band
on it & cleaned up the t.c. wire.
Friday, February 11, 2011
February 11, 2011
Friday, February 11, 2011
Replaced hydraulic hose for core that blew out last night on MP5. Tested OK. Cleaned up, mopped floor.
Ordered spare static charger for MP22, IML.
Ordered new Novatech material loader for new to us Matsui Dryer.
Ordered, received photo eyes and valves for IML fixture to replace pneumatic proxes. Started on installation.
Debugged I/O on new F1 Lite Fan Housing Tester.
Mark McKee
Technical Specialist
Oreck Manufacturing Company
mmckee@oreck.com
PH 931.646.7856
CELL 931.644.5289
FAX 931.646.7615
Wednesday, February 9, 2011
2.8.11 D-shift
MP#10- Pm'd machine and robot, touched up with some paint.
Have a good day!
Sean
Tuesday, February 8, 2011
Ronnie Upchurch
MP-5 Core 2 set switch not making. The mold wasn’t repaired over the weekend, so they had to pull it again for repair. Both switches were bad. Tooling
Replaced them.
MP-15 Lost all manual control function. I found that the mold hanger had over stroked clamp open while setting it up. Also the eject back switch wasn’t made.
I just had to make the switch & go through the clamp position reset procedure.
MP-20 Pre dryer loader not coming on. The load level sensor was out of adjustment.
MP-2 The front zone heat dropped out. The mercury contacts stuck open. “ Tap & Go”
DR-17 Regin over temp alarm. I found out they had just shut it down & moved it to another press without letting it cool down. After it sat & cooled awhile,
It started right up.
New Novatec dryer- Still under warranty. They are sending a new drive motor & speed control. We have to send the old motor & speed control back.
I got a quote for a Novatec loader to go on the Matsui dryer hopper. Waiting for Jerome.
Monday, February 7, 2011
2-6-11 Mike Daniels
Mp13 repaired water manifold. Had to weld 1 port up was messed up too bad to retap.
Mold# 74046 this had a tooling work order but it just had sensor issue which I replaced. And put back in rack.
Mp12 replaced bad slowdown sensor on mold open side. I robbed this switch from Mp17
Need to order sled cylinder rebuild kit for mp15
Worked on PMs rest of night