Friday, February 17, 2012

2.17.12 Sean

Dryers all set that could be set for auto-start. I left a start up sheet for Marty and 3rd shift that indicated which dryers needed to be turned on and which ones were off and not in use.

We had another hydraulic leak on MP#2 core cyclinder hose. I replaced the hose and we cleaned up most of the oil.

Mp#26- Replaced the nozzle heater bands due to a bleedoff. Checked back on it later and there were no further problems with it.

Sean

Thursday, February 16, 2012

2.16.12 Sean

Mp#6- Had more trouble with the gate cutter on the baseplate EOAT scratching the parts. The back stop had loosened again. Tightened it up, no further problems.








Mp#20- Has been having bleedoffs around the nozzle tip. It needs to be changed out to a new nozzle, or the old one re-surfaced when it goes down for a mold change. Keep an eye on it.







Repaired the DME in the shop. The clip in the 3rd spot down inside the terminal connector must have a clip in it regardless of whether it is wired to anything (it is not usually). If it does not, cards will not work correctly in it. In this case, it had one missing.







Finished up the conveyor roller covers in the shop and rolled it back out of the shop.







Cleaned up in the shop, took out the trash and cardboard.







Have a nice day.







Tuesday, February 14, 2012

2.14.12 B-shift Sean

Mp#1- Robot is down until pendant is available.

Nut Press on #10- Replaced a sensor on LH side square nut fixture. Cleaned and inspected it. O.K. to run.

Pm'd Press #5. We are putting loctite on the screws on all the loading receivers on the presses and in the mezzanine to prevent screws from loosening. I am also trying to get around and refill all of the FRL's with oil where needed on robots, etc.

Mp#6- Replaced the rpm tach for the extruder that was busted off. Used the one from MRO.

Have a nice day.

Sean