Monday, May 9, 2011

May 9, 2011

May 9, 2011

 

Worked with Gary on part present sensors for R2 Facia

 

MP1 clamp making noise removed guards at the end of machine, found broken screws in motor gear, gear had slid, belt hanging off, removed broken screws, pulled gear back in place, tighten bolts, greased all fittings on that end, replaced guards, looks OK

 

Mark McKee

Technical Specialist

Oreck Manufacturing Company

1400 Salem Rd

CookevilleTN  38506

mmckee@oreck.com

PH      931.646.7856

CELL  931.644.5289

FAX    931.646.7615

 

Week of May 2nd, 2011

Week of May 2nd , 2011

Replaced FHD board and pressure transducer on MP5.

Rebuilt sled cylinder on MP20.

Ran High Voltage lines on MP22 product arm. Provide means for easily
disconnecting EOAT on insert side.

Valves for Mezanine purge valves are on table.

Conair dryer push button touch pad is on table.

MP24 was faulted and would not clear the error. Ended up switching from
manual to auto and back and then reset cleared.

Mark McKee

Technical Specialist

Oreck Manufacturing Company

1400 Salem Rd

Cookeville, TN 38506

mmckee@oreck.com

PH 931.646.7856

CELL 931.644.5289

FAX 931.646.7615

test

 

 

Mark McKee

Technical Specialist

Oreck Manufacturing Company

1400 Salem Rd

CookevilleTN  38506

mmckee@oreck.com

PH      931.646.7856

CELL  931.644.5289

FAX    931.646.7615