4.11.10 D shift

MP#5- Had the same problem that 3 had the other day with that Decompress Hoses valve-A156. The coil had shot in it as well and blew the fuse. Changed coil and fuse, then restarted, then talked to Marty and Bill about a problem with the cushion moving all over the place in cycle.

Worked on inconsistent cushion problem that many of the technicians have complained about. Decided to inspect the screwtip after discussing it with Marty and Bill. Pulled it out and really could not determine that it was bad, but, put a ball check in it while it was down to eliminate that. It worked, aligned the nozzle/sled back up and tightened everything back down, re-zeroed the screw position and started it back. Had no further problems with cushion.
There is a problem with the injection unit when it sucks the screw back after building a shot, it is making a loud hydraulic "Shuttering" sound. It is really difficult to describe, but you know that there is something wrong. It is running good parts now, but we need to get that injection valve tuned better or something. Open for suggestions. Will look into it further tomorrow.

Continued with water on #26 the rest of the night.

Call if there are any questions.

Sean