Mp#15- Zone 1 overtemp.
Found the problem to be an incorrect thermocouple type. It had a "j" type and it should have been a "k" type.
There were 2 more J type in the MRO location where the K's were supposed to be and I almost made the same mistake that someone else had made, of putting one on. Instead I used a nozzle band K type and put it under the band on the first zone.
It is running good and staying exactly on temperature now.
Fixed the leak on MP#2.
Refilled 17 with oil and cleaned up the oil dry.
Checked out the milacron dryer DR17 and it is fine.
Checked out DR2, looped it out for a few hours and checked the beds, it is fine too.
Sent an email to one metal supplier to see if they can get us some brass peices for the sled shims the right dimensions that I measured tonight.