1/25/11
MP-6-7-8 Vacuumed oil pans.
MP-5 The bolt on the “C” axis pivot backed out & it wasn’t making the limit switch every time. Repaired.
MP-6 The robot kept stopping when “Y” axis started in mold. I found that the “Z” axis was loosing position. I tightened the encoder shaft coupler. OK now.
MP-12 Novatec dryer was running hot- not enough air flow on return from hopper. Bill didn’t want to shut it down to check for blockage in hopper. “Run it till
The wheels fall off !! “
1/25/11
MP-10 The wheel press wouldn’t reset without switching the power off. Mark reassigned a reset in the program. Nuts are still oily, & they still want to run
A faster cycle, & wonder why they have trouble pressing parts that are shrinking too much, & then blame us for the press not having enough pressure-
Same old – same old !
MP-9 Vacuumed oil pan.
MP-2 The robot “X” axis position kept changing. The encoder shaft coupler was loose & the plug tie down only had one screw in it & plug was half way out. Repaired.
MP-3 The nozzle heat was unstable. The tip heater didn’t have a clamp & the T.C. was loose. Installed clamp.
MP-6 The gate cutter index cylinder slide broke. Mark made new mounting plates.
up on night shift. Check for set up before it starts.
No comments:
Post a Comment