Monday, January 30, 2012

1.27/28/29.12 Weekend D-shift Sean

Tried to work on PM's as much as possible, we were short the tech they let go and didn't really have anyone come in until Sunday night. So, I helped them with processing some.

Mp#22-built an eoat for mold#80135 haven't logged it on the sheet yet, but it is stamped with the number.

Mp#6- Had some trouble with the EOAT gate cutting on the base plates. It is sporadically missing the cut on the op.side part. When I say sporadic, I mean every 10th-30th shot it may miss the cut. At this point, I suspect the ejector timer may be messing up because I have caught it once and it looked like the ejectors went back too fast, or the compact cylinders delayed too much before moving the nippers.

Mp#17- The door was causing a  "5200: Confirm stopper plate position" alarm and would cause servo control to loose power. I removed the back door and bent the flag slightly so that it would pass a little closer to the prox. It seemed to help. I noticed that press #1 has a magnetic catch on the door to keep bounce to a minimum. I think we should get one for 17 also.

Give me a call if you have any questions.

Have a great day.

Sean