Monday, April 23, 2012

4.23.12 Sean Kearns

Mp#25- F1 Fan -To Set up the press to run the product distinction system: Set "M1" when the press is in automatic and has finished delivering the (*2)forced rejects to the scrap box. Just push "F1" and it will begin flashing "ON". Do not press enter, just let it flash. After a shot it will remain in "ON". When you are ready to read a sample from a "good" cycle, then press "F2", it will also flash until it has "registered" a good cycle. Then it will remain "ON" as well. Adjust the "M1" value to read just below the "INJ END POSITION" of the "good" part cycle and the "M2"value should be just above it.

We tested the process by allowing the cushion to deviate below the "M1" value by lowering the shot size. It gave an indication of the fault and then delivered the faulty parts to the scrap drop. After the (*6) consecutive shots determined to be bad, it will stop the press and alarm. If the nozzle freezes off and the inj end position goes above the "M2" value, it will also fault and deliver them to scrap drop.

Have a nice day!

Sean