MP#5 Robot- Mike evidently found a loose connection somewhere as the communication problem went away by the time I came in.

Mp#2- Replaced a blown fuse on the 24v4 circuit. They must have smashed a wire when the tool was set on 2nd shift? GMA-5A

Mp#16- Moving -platen has a thread hole damaged on the operator side, needs repaired when down.

Mp#17- Cores were not working on the mold. Both core switches were reading made all the time.
Checked it out and found that the jumpers were still in for core 1. Looked at what was done and already and tied the rest of it together. Wired switches for core 2 inputs, wired control switch in operator panel for core 2, removed necessary jumpers, checked operation. Put a core 2 legend on tghe front of the op station for techs to be advised.

Continued installing safety signs. Need some to put on the R2 fascia label station. I don't know where Mark got the ones for the classic fascia label station?

Have a nice day!