Had some problems with the core set switch not reading correctly.
The symptom was that the set switch would not make at first try in manual, but, when you set it the second time it would make.
I went through checking for loose connections, replaced the switch, and the relay module (110vac), but no change.
We found that pressure was only 500psi.
Although no adjustments had been done on press#10, we adjusted V225 pressure relief valve to 1550 and had no further problems.
This is interesting because the press was running when the fault occurred.