Mp#13- I got it leveled up, still needs the power tied into the robot and checked out for correct operation.
There are two primary side transformer fuses inside the cabinet that need to be pulled out!
I wasn't sure if we were going to add another 480 there also or not?
MP#19- Cores are still not working, looked at it and found tank/pressure lines were backward. I corrected that, still did not work. After looking at prints, it was apparent that we had the wrong style of solenoid valve. We were using a regular 24vdc, looked like what we needed was the 4 wire type the other newer nissei's have on them (with the circuit built in). I attempted to use small relays to isolate the signal from the load of the coils. One side is working but the other side(929) is not putting out a signal. Not sure if it is a program thing or exceeding the 60ma load may have caused a fault, etc.? Ronnie said that when he checked it out, one side works, then if you swap wires to coil, the other side works so it definitely looks like a signal problem at this point.
I tried to clean and organize the shop tonight and put away a bunch of items back into MRO, etc. The filter cart hasn't been checked out but Mark and I discussed getting it going...there was an issue with the motor coming in wired incorrectly and it looked like it had been very hot before. I printed off a ser vice manual and got some info on it.
Call if there are any questions.
Sean