" C " Shift Weekend

 

MP-22  Broken glass on control panel—Ordered new one for Saturday delivery

 

MP-2  Tech had core problems--  checked & found sequence was set wrong.  Also DME hooked up wrong; heater was plugged in to zone 1 – TC was plugged in to

            Zone 2.  After correcting it, found it had a bad heater. Tooling to change it out.

 

MP-13  Tech said when sled was run in, the nozzle heat would drop out. When I went to check on it, Bill had started it up & it was OK. He said to let it run.

           ( For future reference )

 

I called Nissei about oiler fittings—They said they would send the right ones & for us to just keep the other fittings.

 

MP-22   The control panel glass & sheet came in---  Installed & checked out.  Also made a cover for it.  I need more hinges to make covers for the other ones.

 

MP-24  Installed a plug for the mold cores to the machine.

 

MP-17 Cleaned up oil jug overflow on clamp end.

 

MP-23  Weak vacuum on eoat suction cups--- tightened up all the fittings—OK

 

MP-23 Replaced the nozzle heater band.

 

MP-22  Could not change the screw back position.  I had to reset the injection scale. ( Press & hold the alarm reset while running the screw all the way back, then all the

           way forward, release reset button, then you can change the setting ).        

           

 

MP- 22  Getting a lot of color swirls in natural bag stiffener.  It wouldn’t purge out. I pulled the nozzle tip & the adapter. The adapter wasn’t seating, so I cleaned it out &  

             had tooling reface it. I reinstalled it & they were starting it up on “ D “ shift.

 