MP-22 Broken glass on control panel—Ordered new one for Saturday delivery
MP-2 Tech had core problems-- checked & found sequence was set wrong. Also DME hooked up wrong; heater was plugged in to zone 1 – TC was plugged in to
Zone 2. After correcting it, found it had a bad heater. Tooling to change it out.
MP-13 Tech said when sled was run in, the nozzle heat would drop out. When I went to check on it, Bill had started it up & it was OK. He said to let it run.
( For future reference )
I called Nissei about oiler fittings—They said they would send the right ones & for us to just keep the other fittings.
MP-22 The control panel glass & sheet came in--- Installed & checked out. Also made a cover for it. I need more hinges to make covers for the other ones.
MP-24 Installed a plug for the mold cores to the machine.
MP-17 Cleaned up oil jug overflow on clamp end.
MP-23 Weak vacuum on eoat suction cups--- tightened up all the fittings—OK
MP-23 Replaced the nozzle heater band.
MP-22 Could not change the screw back position. I had to reset the injection scale. ( Press & hold the alarm reset while running the screw all the way back, then all the
way forward, release reset button, then you can change the setting ).
MP- 22 Getting a lot of color swirls in natural bag stiffener. It wouldn’t purge out. I pulled the nozzle tip & the adapter. The adapter wasn’t seating, so I cleaned it out &
had tooling reface it. I reinstalled it & they were starting it up on “ D “ shift.