Thursday, July 15, 2010

MP21 Toshiba ISE250N Procedure to Make Screw Return to Full Back Position

MP21 (TOSHIBA ISE250N) Screw Back Position Correction

 

1)   With the power on, open the Main Control Cabinet Doors,

 

2)       On the inside of the LH door, locate a blue tuning pot, with the numbers 0-9,

it is extreme upper LH side of injection control board under a terminal strip, dial the

pot to the #1 position.

 

3)       Under the blue tuning pot, locate and depress, a push button labeled “3SW”.

 

4)       Now, over on the Data Cell Display, punch in code 32 and change the value to 1.0 or .5

Record the original value.

 

5)      Now punch in code 33 and change the value to 40.  Record the original value.

Make sure the value you enter are retained.

 

6)      Turn the tuning pot back to the “0” position.

 

7)  Depress the “3SW” push button.  You are finished.

 

Original Values on July 14, 2010 were Code 32 = 4.0 and Code 33 = 16.

 

Mark McKee

Technical Specialist

Oreck Manufacturing Company

1400 Salem Rd

CookevilleTN  38506

mmckee@oreck.com

PH      931.646.7856

CELL  931.644.5289

FAX    931.646.7851

 