MP-10 Robot part grip not working. It was getting a signal, but no air was going through the valve. I took the solenoid valve apart & cleaned it out. OK now.
MP-23 No nozzle heat—Jason changed the tip heater out; it must have grounded out. I reset the breaker. Working OK.
DR-27 The loader had no vacuum. I found the flapper valve had broken off. I made a new one & installed it.
DR- 10 ( The 100# dryer in the shop ) I checked the power supply control voltage, cleaned the edge connectors on the I.O. & mother boards, found the regin. temp
probe plugged into the wrong spot, & installed a new control door cover. Test ran it in the shop for 3 or 4 hours. Ran good.
The hose reducer for the new Novatec dryer came in. I installed it. They can have it back now.
I made up a purchase req. for another Novatec loader.