MP#2- Zone #3 - (10p.m.)dropped out. Checked the circuit, it was good. Mercury relay appeared to be magnetized. Pecked on it, it resumed heating, no further problems.
Mp#20- The part drop tray under press needed an angle board to divert the parts towards the operator. The original plexiglas part had broken. Used it for a template and constructed a new one from Aluminum sheet, transfered the handles to it and installed.
Continued with PM's on presses 13 and 14 tonight, and painted some on the gray presses.
Call if there are any questions.
Sean