Sunday, January 17, 2010

1.17.10 night shift D

MP#10 - robot was stopping above conveyor after part delivery. Ronnie and I looked at it briefly,didn't see anything obvious. We adjusted tracking on Z-belt. I did a PM on it after they shut it down an hour later and dry cycled it for about 20 minutes, it did not stop anymore. Will keep an eye on it.

MP#2- Robot had no apparent alarms but would not give permission to close to machine, turned out that someone had left the robot in "DRY CYCLE" mode.

MP#7- looked at the baseplate tool, had open thermocouples, we checked boxes, cables, etc, turned out to be open TC's in the mold. They are running it in Manual.

I vacuumed out all the robot control cabinets and found 3 cooling fans bad.
I could not locate any in MRO so we need to order those. Also need a few other items to complete some workorders so I will leave Mark a list Monday morning.

I mounted a tray on the crane column behind the Welder on #12 to store nest screws so they will be 5-S compliant.

Worked on PM's and misc. oddball requests from the Moldsetter, process techs and team leader throughout the night. Call if there are any questions.

Sean.