2.18.10 nights Sean

#10 robot was stopping over the conveyor and screen was displaying
"robot not on". It would not power up at all. Got in the cabinet and traced down the mcr circuit to one of the NC switches on the y or z axis. Replaced the Y axis reference switch and had no further trouble from it.

Pulled hoses from eagle top cover tool that is going out today for engineering changes. I made a detailed drawing of hoses but they are still together in one bunch and is fairly self explained when looking at them. They are in a blue tote.

Finished putting up the signs for the disconnect locations at machines.
If there are any problems with them we'll be glad to make changes as needed.

GR-20 : Replaced start push button. Replaced broken caster with a used salvaged one. Put the panel screws back on it. Green tagged it after starting it and checking operation.

The conveyors in the shop are 200vac. They are rated at 25watts. The star robots have a maximum requirement of 500va (or.55%x500=roughly 275 watts) and the transformer is only rated for 500va...so they could only use them if they do not run the robot at the same time.

Call if there are any questions.

Sean