Mp#5- Fhd current input #1 exceeds limits alarm several times.
Pump overloads tripped a few times. We reset the pump and restarted machine and worked with EOAT to get parts.
When Josh came in at 11pm, he said that the throttle valve had been opened up to the extruder and this may have caused some pressure increases frm the pump. Possibly this could be why the pump was tripping out ("over-current").
He printed off the Milacron runoff data for the fhd and made several changes to hidden board values including a reduction in pump pressures output. More specifically he can let you know what he did.
It ran good without stopping since then until 2a.m. when it ran out of material.
Josh wants to make some adjustments to it when it goes down. It just went down for lack of material so we may be able to do something today.
Mp#26- made a support bracket for the thermolator process lines.
Mp#20- ran out of liquid color at 5 a.m. so may transfer the nest over to the other hot stamp press today and possibly look into the control issues with that old hot stamp press that keeps loosing control power or heats dropping out on it..
Cleaned up some oil and swept up shop.
Call if there are any questions.
Sean
No comments: