Sunday, August 29, 2010

" C " Shift - Weekend

MP-20  The cycle start timer wasn’t working. We saw input 14 on the plc flickering. Mark traced the wire & found a loose connection in the robot wiring.

 

MP-5 Added hydraulic fluid.

 

MP-2 & 6   PMed.

 

MP-20  Mold # 77015 – The DME heater plug on the mold had a broke pin – zone 6. I replaced the plug. The wires were short in the box so I had to add another splice in       the wiring.  I’ll have tooling let me

               know  when  the mold comes back & I’ll fix it right.

 

MP-5  Pump motor overload tripped. Injection valve – off  fault.  Mark said the pack time was  set too high.  He lowered the time & it hasn’t stopped again.

 

MP-3  Zone 3 barrel temp was running away. The mercury contact was stuck- replaced it.

 

I worked on the bag clip hot stamp. The heat kept dropping out. I found a loose solder connection on the board. I re- soldered it & I have been trying it out

      In the shop. So far I hasn’t cut off.

 

 

 

   R. Upchurch  