Saturday, October 23, 2010

Ronnie Upchurch

              10/22/10

 

MP-16   Installed a flow control valve on the eject. retract line.

 

MP-21  They changed the nozzle tip from a button tip to a  2”.  I installed a tip heater band and replaced the adapter band that was burned out.

 

MP-17 Cleaned up oil, emptied jug, & replaced pads…………………………..

 

MP-4  At 5pm the tech told me the robot crashed. I checked & the “Y” axis had extended to the mold & hit the stationary side. It broke the “C” air

          cylinder, two vacuum fittings, & bent two suction cup brackets. I removed the eoat & cylinder & turned it over to Sean Man.

 

              10/23/10

 

MP-9  The “Z” axis set point was drifting. I checked the encoder – everything was tight. I tightened the “Z” axis belt & rebooted the robot. It looks

          consistent now.

 

MP-22  The hotstamp heats kept going off. I checked all the heater connections. I reseated the T.C. plug on the board. It’s running & hasn’t cut off

            in four hours.

 

MP-11  The PS-2 pressure switch on the injection unit quit working. I replaced it.

No comments:

Post a Comment